← Back to section · Research Resources

Public Quantum Hardware Benchmark Data: Vendor Disclosures and Third-Party Suites

Most quantum hardware performance numbers are published by the vendors themselves; third-party benchmark suites are the rare counterweight. This guide surveys public calibration data from vendors such as IBM, result repositories from QED-C and other third-party suites, and the timestamps, revisions and selection biases to check when using self-reported data.

Published 22 November 2026 · 5 min read · PQ Frontier

Public Quantum Hardware Benchmark Data: Vendor Disclosures and Third-Party Suites
AI-generated site artwork
Video explainer · Public Datasets: verify before you use

A body of data that leans on self-reporting

Most datasets on the cryptography side have neutral maintainers; quantum hardware is different. The finest-grained, most current data comes from the vendors themselves. Major quantum computing platforms publish calibration data for their in-service devices on platform pages or through interfaces — each qubit’s frequency, readout error rate, single- and two-qubit gate error rates, coherence times, all individually queryable. This data is the primary material for studying hardware progress, reproducing experimental conditions and comparing devices, but it is also the vendor’s shop window: what gets published, when it updates and how it is summarized all sit with the publisher. Bring that awareness to any research use.

The main sources

Vendor calibration and metric data. IBM Quantum is the representative case: its platform publishes calibration snapshots and backend properties for each device, plus aggregate metrics such as quantum volume and CLOPS (circuit layer operations per second), and newer conventions such as layer fidelity. Other vendors publish device specification pages and whitepaper data in their own formats. Calibration snapshots update at high frequency — devices are recalibrated daily, so data downloaded yesterday is already a historical record today.

Third-party benchmark result repositories. QED-C’s (Quantum Economic Development Consortium) application-oriented benchmark suite runs a set of standard application circuits uniformly across many vendors’ hardware, with results and code hosted together in a public repository — one of the few cross-vendor datasets with an open methodology. Academic suites such as SuperMarQ, and QASMBench (covered in this site’s dataset overview), belong to the same layer: their shared value lies less in the numbers than in applying one method and one workload set to every device alike.

Data accompanying papers and preprints. Benchmark charts and supplementary data published with device papers have passed peer review and are more reliable than marketing pages, but they are the least current, often lagging the device’s present state by a year or two.

Other independent yardsticks. Beyond vendors and QED-C, several efforts try to stay neutral: the Q-score proposed by a European vendor uses the size of solvable optimization problems as its scale; national laboratories and university groups publish same-conditions re-measurements of multiple devices in papers; and industry analyst firms compile device parameter tables. None matches the vendor platforms in sample size or update frequency, but precisely because their positions differ, they are indispensable second and third sources when cross-checking vendor numbers. Writing “who measured it” next to every figure is the basic discipline for using this data.

Research uses in this field

For this site’s readers, the most direct use is anchoring quantum-threat assessment in reality: resource-estimation articles state what error rates and scale breaking RSA-2048 would require, and hardware data shows how far current devices are from that line and at what slope they are closing in. Tracking how one device revision’s calibration data moves over time says more about the true pace of progress than any single-point promotional number. The data also serves reproducibility: when reporting experimental results on a device, attaching the calibration snapshot from the run date is what lets later readers understand the noise conditions under which the results were obtained.

What to check before using it

First, the timestamp. Calibration data drifts daily, so every citation needs the data date; comparing two devices using data from different dates is unsound from the start. Second, the device revision: devices under the same name change chips and revisions, and the version label on platform pages is the key to telling them apart — ignore it, and “this device improved” often turns out to be two machines treated as one. Third, metric definitions: aggregate metrics such as quantum volume have had their definitions revised, and identically named metrics from different vendors are not necessarily the same convention; newer measures such as layer fidelity cannot be converted directly into older ones. Fourth, selection bias: vendors tend to showcase the best qubit subsets and best time windows, and the value of third-party suites is precisely that a uniform workload squeezes that bias out — when a striking number has only a self-reported source, ask whether a third party has run it. Fifth, access form: some platforms’ fine-grained calibration data requires a registered account and interface access, so check the platform terms on academic use and redistribution before bulk use.

The evolution of the metrics is itself data

This body of data has one more distinctive dimension: the metric system keeps changing, and the trajectory of those changes is as informative as the numbers. Vendors first competed on raw qubit counts; the community then moved to composite measures such as quantum volume, which tried to package qubit count, connectivity and gate quality into one number; later came speed measures (CLOPS) and finer-grained conventions such as layer fidelity and error per layered gate (EPLG), each closer to “overall behavior when running real circuits.” Every switch of convention breaks the direct comparability of older numbers, and a vendor’s debut figures under a new convention tend to be its most flattering — the easiest place to be misled when reading historical data: in a decade-long “progress curve” whose metric definition changed three times midway, much of the slope may come from definitions rather than hardware. The rigorous practice is to connect points only within one convention, and across conventions to anchor instead on raw calibration quantities — single- and two-qubit gate error rates, coherence times — whose definitions are stable and comparable across eras. Third-party suites that keep running the same set of application circuits across all vendors for years derive their historical value from exactly this: they are among the few time series that have not drifted with vendor conventions.

References

Tags: quantum hardwarebenchmarksQED-Ccalibration data