← Back to section · Standards & Specifications

How to Read a FIPS: Normative Wording, the Meaning of Approval, and the Division of Labour in the Standards Family

The difference between shall and should, what "approved" means in procurement law, how the FIPS and the SP 800 series divide their work, and what changed between draft and final — a method that applies to reading any algorithm standard.

Published 22 November 2026 · 6 min read · PQ Frontier

How to Read a FIPS: Normative Wording, the Meaning of Approval, and the Division of Labour in the Standards Family
AI-generated site artwork
Video explainer · Algorithm Standards: the lattice behind parameters

Handed a two-hundred-page FIPS, most people jump to the algorithm pseudocode. But the sentences that actually decide whether an implementation is “compliant” are often scattered in clauses outside the pseudocode. This article offers a method of reading: first the wording, then the scope of approval, and finally locating the FIPS within the family of documents it belongs to. The method applies to FIPS 203, 204 and 205, and to any algorithm standard to come.

First layer: normative wording decides the hardness of a clause

The English of a standard text (and of any rigorous translation) follows strict conventions for modal verbs. Shall marks a mandatory requirement: the implementation must do it, and failing to do so means non-compliance. Shall not is an explicit prohibition. Should is a recommendation: departing from it calls for a reason, but does not by itself cause non-compliance. May marks an allowed option. This convention comes from the common practice of international standards writing, and a FIPS declares its force in its introduction or references.

When reading a standard, it is worth first circling all the shall clauses and reading through them. In FIPS 203, for example, the mandatory clauses include: key generation must use an approved random source, only three parameter sets are approved, K-PKE must not be used standalone, and decapsulation must perform the specified input checks. Sentences like these are few, yet they are the entire basis of compliance judgements; the long stretches of pseudocode and explanatory text exist to make these clauses executable. By contrast, passages about performance hints and implementation techniques are mostly written in an explanatory tone, and while reading one can keep clear about “this is a requirement” versus “this is background.”

One more detail: the pseudocode in a standard is itself normative text. When the prose and the pseudocode admit divergent readings, implementers should follow the more precise one and report the issue through NIST’s errata channels — a FIPS continues to be maintained with errata and clarifications after publication, which is evidence that a standard is “alive.”

Second layer: the exact meaning of “approved”

A FIPS uses the word approved repeatedly, and it is not an adjective but a legal status. A FIPS is approved and published by the U.S. Secretary of Commerce, under the federal information security management framework: information systems of federal agencies may use only “approved” cryptographic algorithms and validated cryptographic modules. In the text, the granularity of approval is very fine: what is approved is a particular parameter set of a particular algorithm, in a particular mode, used together with approved random sources and approved hash functions.

This explains the many seemingly conservative restrictions in standard texts: why parameters are limited to three choices, why internal components are marked “not approved for standalone use,” and why the pre-hash mode gets its own section of itemized rules. Under approval semantics, what the text does not say is not “presumably allowed” but “outside the scope of approval.” The private sector is not bound by federal procurement law, but compliance frameworks in industries such as finance and healthcare cite FIPS extensively, so the practical reach of the approval boundary extends far beyond federal systems themselves.

Third layer: the division of labour between FIPS and SP 800

A FIPS answers only “what the algorithm is.” How algorithms are used inside systems is answered by NIST’s SP 800 series of Special Publications: the full life cycle of key management is in SP 800-57, random bit generation in the SP 800-90 series, transition arrangements for algorithms in protocols and systems in SP 800-131A, the conditions for using stateful hash-based signatures separately in SP 800-208, and migration roadmaps in reports such as NISTIR 8547.

So “conforms to FIPS 203” is only one corner of the compliance picture: a system can implement ML-KEM correctly byte for byte and still be non-compliant overall because its random source fails SP 800-90 requirements, or its key storage fails SP 800-57. A habit worth forming when reading standards: whenever a FIPS cites an SP, that citation is the interface to a compliance chain, and the reading is not finished until you follow it.

Finally, the difference between drafts and finals deserves mention. Before a FIPS is finalized it is published in draft form for public comment; the drafts of FIPS 203, 204 and 205 appeared in August 2023 and the finals in August 2024 — during which algorithms were renamed (Kyber became ML-KEM) and individual parameters and byte-encoding details were adjusted. Citing a standard requires stating the version and year; implementing from a draft as if it were the final is a classic source of interoperability accidents.

A walkthrough: FIPS 204 as the example

Running this method once on FIPS 204 looks roughly like this path. First, read the introduction and the approval clauses: confirm that the approved objects are the three parameter sets ML-DSA-44, 65 and 87, and that both the pure and pre-hash modes are within the scope of approval. Next, circle the shall clauses: the context-string parameter must be used in signing (it may be empty, but the parameter must exist and be processed), the way the random value rnd is generated, the range checks that verification must perform — listed one by one, these form the embryo of a compliance checklist. Then read the interface chapters: the division between external and internal functions decides which parts must be tested and which parts are assembled only at deployment time. Then follow the citation chain outward: random sources to the SP 800-90 series for their requirements, key management to SP 800-57, module boundaries to FIPS 140-3. Only at the end read the algorithm pseudocode itself — and by then you are reading it with the question “which steps correspond to which shall” in mind, at a completely different efficiency.

This path also serves to evaluate third-party “compliance claims”: when someone claims conformance to FIPS 204, first ask whether the parameter sets and modes are within the scope of approval, then ask about the random source and module-validation status, and only lastly about implementation details of the algorithm. Reverse the order, and it is easy to be dazzled by the completeness of implementation details while missing an exclusion at the boundary.

Versions, errata, and the “living standard”

A final reading rule concerns the time dimension. A FIPS is not frozen after publication: NIST continues to clarify the text through errata sheets, implementation guidance and Q&As, and ACVP test requirements are updated with implementation experience. When reading a standard, confirm you hold the latest version and check the companion pages for errata records. The differences between the 2023 drafts and the 2024 finals (renaming, parameter fine-tuning, encoding adjustments) have already demonstrated it once: texts one year apart can yield an entire set of non-interoperable implementations. Treating the version number and publication date as part of citing a standard is the most basic professional habit in this field.

Conclusion

The correct order for reading a FIPS is: first filter out the mandatory clauses with the normative wording, then draw the boundary with the approval semantics, and finally complete the picture along the citation chain into the SP family. The pseudocode can be read last — it answers “how to compute,” while the first three layers answer “what counts.” In the compliance world, the second question always comes before the first.

Tags: FIPSnormative wordingcomplianceSP 800